ARO PW20P-YXS-XXX — 2 inch non-metallic family
PW20P-YXS-XXXARO PW20P-YXS-XXX is a 2-inch air-operated double diaphragm pump family in the Specialty Series. Wetted housing options include Polypropylene / PVDF.
- Nominal port size
- 2 inch
- Family maximum flow
- 184 gpm (696 lpm)
- Housing options
- Polypropylene / PVDF
Know the pump.
Construction & fluid path
Listed fluid connection options: ANSI / DIN flange.
Performance & operating point
The published family maximum flow is 184 gpm (696 lpm). The listed maximum working pressure is 120 psig (8.3 bar). Maximum flow and maximum pressure are separate ratings. The operating flow depends on discharge pressure, the available air supply, fluid properties and the selected configuration.
Configuration selection
This record describes a product family or model pattern. Select the complete ordering code and confirm its wetted materials, connections and operating limits before specifying a pump.
Specifications at a glance.
Review materials, connections and operating limits for your duty point.
Identification
| Brand | ARO |
|---|---|
| Model / order number | PW20P-YXS-XXX |
| Series | Specialty Series |
| Nominal port size | 2 inch |
| Family maximum flow | 184 gpm (696 lpm) |
| Housing options | Polypropylene / PVDF |
| Drive type | Pneumatic |
| Working pressure | 120 psig (8.3 bar) |
| Connection standard | ANSI / DIN flange |
Performance
| Ratio | 1:1 |
|---|---|
| Maximum outlet pressure | 120 psig (8.3 bar) |
| Maximum Dry Suction Lift | 19.5 feet (5.9 meters) |
| Displacement per cycle @ 100 psig | 1.4 gal. (5.3 lit.) |
| Maximum particle size | 1/4” dia. (6.4 mm) |
| Maximum flow rate (flooded inlet) | 184 gpm (696 lpm) |
| Maximum air inlet pressure | 120 psig (8.3 bar) |
| Maximum material inlet pressure | 10 psig (0.69 bar) |
Materials & construction
| Wetted body options | Polypropylene / PVDF |
|---|
Connections
| Fluid Ports Inlet/Outlet | 2” ANSI/DIN Hybrid Flange |
|---|---|
| Air inlet | 3/4 - 14 NPT |
Additional specifications
| Nominal port size | 2 in |
|---|---|
| Pump architecture | Air-operated double diaphragm |
Maximum flow and maximum pressure are separate ratings; they do not describe one simultaneous operating point.
Make the right selection.
Share the fluid, required flow, discharge pressure and temperature with Kevin.