WILDEN 02-11439
PX220/AAAAA/TSU/TF/ATF/0677WILDEN 02-11439 is a 1-inch air-operated diaphragm pump in the Pro-Flo X series. This configuration uses an aluminum wetted housing and PTFE diaphragms. The complete ordering configuration is PX220/AAAAA/TSU/TF/ATF/0677.
- Nominal port size
- 1 inch
- Maximum flow
- 211.98 L/min
- Wetted housing
- aluminum
- Diaphragm material
- PTFE
Know the pump.
Construction & fluid path
The pump has bolted construction. Valve material: PTFE. Valve seat material: aluminum.
Performance & operating point
The published maximum flow is 211.98 L/min. Maximum flow and maximum pressure are separate ratings. The operating flow depends on discharge pressure, the available air supply, fluid properties and the selected configuration.
Specifications at a glance.
Review materials, connections and operating limits for your duty point.
Identification
| Brand | WILDEN |
|---|---|
| Model / order number | 02-11439 |
| Series | Pro-Flo X |
| Full configuration | PX220/AAAAA/TSU/TF/ATF/0677 |
| Nominal port size | 1 inch |
| Maximum flow | 211.98 L/min |
| Wetted housing | aluminum |
| Diaphragm material | PTFE |
| Drive type | Pneumatic |
| Construction | Bolted |
| Valve material | PTFE |
| Valve seat material | aluminum |
Performance
| Family maximum flow (gpm) | 56 |
|---|
Materials & construction
| Wetted path material | Aluminum |
|---|---|
| Construction code | AAAAA |
| Diaphragm code | TSU |
| Valve / flap code | TF |
| Valve / flap material | PTFE |
| O-ring / gasket material | PTFE |
| Outer piston material | Aluminum |
Connections
| Nominal fluid connection size (in.) | 1 |
|---|
Dimensions & weight
| Listed pump weight (kg) | 9.9792 |
|---|
Additional specifications
| Product family | Pro Flo X |
|---|---|
| Seat / seal code | ATF |
| Special option code | 0677 |
| Air-system service kit | 02-9988-99 |
| Wetted-part service kit | 02-9814-55-203 |
Maximum flow and maximum pressure are separate ratings; they do not describe one simultaneous operating point.
Make the right selection.
Share the fluid, required flow, discharge pressure and temperature with Kevin.