WILDENPro-Flo® SHIFT
WILDEN 15-12671
Ordering configuration
XPS15/SSNNN/BNS/BN/BNWILDEN 15-12671 is a 3-inch air-operated diaphragm pump in the Pro-Flo® SHIFT series. This configuration uses a stainless steel wetted housing and Buna-N diaphragms. The complete ordering configuration is XPS15/SSNNN/BNS/BN/BN.
- Nominal port size
- 3 inch
- Wetted housing
- stainless steel
- Diaphragm material
- Buna-N
THE CONFIGURATION
Know the pump.
Construction & fluid path
The pump has clamped construction. Fluid connection specification: NPT threaded. Check ball material: Buna-N. Valve seat material: Buna-N.
TECHNICAL DATA
Specifications at a glance.
Review materials, connections and operating limits for your duty point.
Identification
| Brand | WILDEN |
|---|---|
| Model / order number | 15-12671 |
| Series | Pro-Flo® SHIFT |
| Full configuration | XPS15/SSNNN/BNS/BN/BN |
| Nominal port size | 3 inch |
| Wetted housing | stainless steel |
| Diaphragm material | Buna-N |
| Drive type | Pneumatic |
| Construction | Clamped |
| Connection standard | NPT |
| Connection type | Threaded |
| Check ball material | Buna-N |
| Valve seat material | Buna-N |
Performance
| Min Operating Temperature (°F) | 10 |
|---|---|
| Max Operating Temperature (°F) | 180 |
| Self Priming | YES |
Materials & construction
| Technical Construction | CLAMPED |
|---|---|
| Wetted Path Material | STAINLESS STEEL |
| Diaphragm Design | TRADITIONAL |
| Diaphragm Stroke | Full-Stroke |
| Valve Type | VALVE BALL |
| Valve Material | Buna-N |
| O-ring / gasket material | Buna-N |
| Outer Piston Materials | STAINLESS STEEL |
| Air Side Material | ALUMINUM|NICKEL PLATED |
| Hardware Material | STAINLESS STEEL |
| Muffler Material | Aluminum |
Connections
| Nominal fluid connection size (in.) | 3 |
|---|---|
| Inlet Size (in.) | 3 |
| Inlet Orientation | CENTER HORIZONTAL BACK |
| Discharge Size (in.) | 3 |
| Discharge Orientation | CENTER HORIZONTAL FRONT |
Dimensions & weight
| Shipping Weight (lbs) | 187 |
|---|
Additional specifications
| Product family | METAL INDUSTRIAL |
|---|
Maximum flow and maximum pressure are separate ratings; they do not describe one simultaneous operating point.
LET’S CHECK THE DETAILS
Contact Kevin Make the right selection.
Share the fluid, required flow, discharge pressure and temperature with Kevin.