WILDENPro-Flo® SHIFT
WILDEN 04-14162
Ordering configuration
XPS4/AZAAA/LEL/TF/ATFWILDEN 04-14162 is a 1.5-inch air-operated diaphragm pump in the Pro-Flo® SHIFT series. This configuration uses an aluminum wetted housing and PTFE diaphragms. The complete ordering configuration is XPS4/AZAAA/LEL/TF/ATF.
- Nominal port size
- 1.5 inch
- Wetted housing
- aluminum
- Diaphragm material
- PTFE
THE CONFIGURATION
Know the pump.
Construction & fluid path
The pump has clamped construction. Fluid connection specification: NPT threaded. Check ball material: PTFE. Valve seat material: aluminum.
TECHNICAL DATA
Specifications at a glance.
Review materials, connections and operating limits for your duty point.
Identification
| Brand | WILDEN |
|---|---|
| Model / order number | 04-14162 |
| Series | Pro-Flo® SHIFT |
| Full configuration | XPS4/AZAAA/LEL/TF/ATF |
| Nominal port size | 1.5 inch |
| Wetted housing | aluminum |
| Diaphragm material | PTFE |
| Drive type | Pneumatic |
| Construction | Clamped |
| Connection standard | NPT |
| Connection type | Threaded |
| Check ball material | PTFE |
| Valve seat material | aluminum |
Performance
| Min Operating Temperature (°F) | 40 |
|---|---|
| Max Operating Temperature (°F) | 220 |
| Self Priming | YES |
Materials & construction
| Technical Construction | CLAMPED |
|---|---|
| Wetted Path Material | ALUMINUM |
| Diaphragm Design | PTFE IPD |
| Diaphragm Stroke | Reduced-Stroke |
| Valve Type | VALVE BALL |
| Valve Material | PTFE |
| O-ring / gasket material | PTFE |
| Outer Piston Materials | NO OUTER PISTON |
| Air Side Material | ALUMINUM |
| Hardware Material | DIAPHRAGM DEPENDENT |
| Muffler Material | Aluminum |
Connections
| Nominal fluid connection size (in.) | 1.5 |
|---|---|
| Inlet Size (in.) | 1.5 |
| Inlet Orientation | CENTER HORIZONTAL BACK |
| Discharge Size (in.) | 1.5 |
| Discharge Orientation | CENTER VERTICAL |
Dimensions & weight
| Shipping Weight (lbs) | 46 |
|---|
Additional specifications
| Product family | METAL INDUSTRIAL |
|---|
Maximum flow and maximum pressure are separate ratings; they do not describe one simultaneous operating point.