Shanghai WILLEE Pump Co., Ltd.Diaphragm pumps & parts · Shanghai, Chinawilleepump@gmail.com
WILLEEPUMP TECHNOLOGY
ARO EP10-PXXXX-XXX-XXX — 1 inch non-metallic family — product reference photograph
Product reference photograph. Appearance and internal components depend on the exact ordering configuration.
AROEVO 300

ARO EP10-PXXXX-XXX-XXX — 1 inch non-metallic family

Model patternEP10-PXXXX-XXX-XXX

ARO EP10-PXXXX-XXX-XXX is a 1-inch electric triple diaphragm pump family in the EVO 300 series. Wetted housing options include polypropylene.

Nominal port size
1 inch
Family maximum flow
54 gpm (204 lpm)
Housing options
polypropylene
THE CONFIGURATION

Know the pump.

Construction & fluid path

Listed fluid connection options: ANSI / DIN flange.

Performance & operating point

The published family maximum flow is 54 gpm (204 lpm). Maximum flow and maximum pressure are separate ratings. The operating flow depends on discharge pressure, the available drive power, fluid properties and the selected configuration.

Configuration selection

This record describes a product family or model pattern. Select the complete ordering code and confirm its wetted materials, connections and operating limits before specifying a pump.

TECHNICAL DATA

Specifications at a glance.

Review materials, connections and operating limits for your duty point.

Identification

ARO EP10-PXXXX-XXX-XXX — 1 inch non-metallic family — Identification
BrandARO
Model / order numberEP10-PXXXX-XXX-XXX
SeriesEVO 300
Nominal port size1 inch
Family maximum flow54 gpm (204 lpm)
Housing optionspolypropylene
Drive typeElectric
Connection standardANSI / DIN flange

Performance

ARO EP10-PXXXX-XXX-XXX — 1 inch non-metallic family — Performance
Maximum flow rate (flooded inlet)54 gpm (204 lpm)
Displacement per cycle @ 80 psig0.25 gal. (0.95 lit.)
Maximum material inlet pressure60 psig (4.14 bar)
Maximum Average Working Pressure120 PSIG (8.3 bar)
Maximum outlet working pressure (piping design limit)180 psig (12.4 bar)
Maximum particle size1/8" dia. (3.3mm)
Wet suction lift28 ft (8.5 m)
Dry suction lift14 ft (4.3 m)
Gear Ratio12.4:1
Type and Classification (For hazardous configurations only. Please note: VFD should not be installed in a hazardous area.)II (2) G [EX e] [Ex d] [Ex n] II (2) D [Ex tb] [Ex tc] II (2) G [EX e] [Ex d] [Ex n] II (2) D [Ex tb] [Ex tc] II (2) G [EX e] [Ex d] [Ex n] II (2) D [Ex tb] [Ex tc]

Materials & construction

ARO EP10-PXXXX-XXX-XXX — 1 inch non-metallic family — Materials & construction
Wetted body optionsPolypropylene
Diaphragm / Ball Check Size1" (25.4 mm) equivalent

Connections

ARO EP10-PXXXX-XXX-XXX — 1 inch non-metallic family — Connections
Fluid Inlet / Outlet Hybrid - internal threadANSI / DIN Hybrid flange

Dimensions & weight

ARO EP10-PXXXX-XXX-XXX — 1 inch non-metallic family — Dimensions & weight
Pump weight, without motorEP10-EXXXX-XXX-XXA 225 lbs (102 kg) EP10-PXXXX-XXX-XXA 231 lbs (105 kg)
Weight380V-500V Model / Enclosure Size Type: A5 31.5 lbs (14.3 kg) 200V-240V Model / Enclosure Size Type: A5 31.5 lbs (14.3 kg) 525V-600V Model / Enclosure Size Type: A5 31.5 lbs (14.3 kg)

Additional specifications

ARO EP10-PXXXX-XXX-XXX — 1 inch non-metallic family — Additional specifications
Nominal port size1 in
Pump architectureElectric triple diaphragm
ModelsPolypropylene
Stroke1.34 in (34 mm)
Peak Efficiency62%
Maximum Pump Speed198 rpm
Mounting Dimension / Circumference Radius3 equally placed 0.63” (∅ 16 mm) hole on 24.88” (∅ 632 mm) B.C. / 26.48" (672.6 mm)
Dimensions *Pump with Gear Motor (not including hazardous encoder)Height: 17.71" (449.9 mm) until outlet flange *40.55" (1030 mm); Hazardous Encoder Height: 5.09" (129.4 mm) Length: 28.48" (723.5 mm) Width: 31.04" (788.31 mm)
Rated Power / Phase / Voltage / Efficiency2.2Kw / 3 Phase / 400V / IE3
Type and ClassificationINERIS 10 ATEX 0025X (Gas) II 2 D EX tb IIIC T125° C Db Dust: II 2 D EX tb IIIC T125° C Db (Gas) CLASS 1, DIV 2, GROUPS C,D CLASS 1, ZONE 1, AEx db IIB T4 Gb (Dust) ZONE 21, AEx, tb IIIC T135°C Db
Encoder5V 1024 pp
Motor Amps @ 400V / 50Hz4.45 A
Dimensions for Standard & Hazardous Duty (Not including hazardous duty encoder)Height: 21.71" (551.5 mm) Length: 8.22" (209 mm) Width: 8.22" (209 mm)
Dimensions of Hazardous Duty Encoder5.09" (129.4 mm)
Rated Power / Phase / Voltage3 Kw / 3 Phase / 380V-500V 3 Kw / 3 Phase / 200V-240V 3 Kw / 3 Phase / 525V-600V
Frequency50Hz / 60Hz 50Hz / 60Hz 50Hz / 60Hz
Maximum VFD Speed82Hz 82Hz 82Hz
VFD Input Amps (Cont. @ 441-500V)5.7 A @441-500V 11.3 A @200-240V 5.2 A @525-600V
VFD Input Amps (Inter. @ 441-500V)9.1 A @441-500V 18.1 A @200-240V 8.3 A @525-600V
DimensionsEnclosure Size Type: A5 Height: 16.5" (420 mm); Width: 9.5" (242 mm); Depth: 9.10" (231.3 mm) Enclosure Size Type: A5 Height: 16.5" (420 mm); Width: 9.5" (242 mm); Depth: 9.10" (231.3 mm) Enclosure Size Type: A5 Height: 16.5" (420 mm); Width: 9.5" (242 mm); Depth: 9.10" (231.3 mm)

Maximum flow and maximum pressure are separate ratings; they do not describe one simultaneous operating point.

LET’S CHECK THE DETAILS

Make the right selection.

Share the fluid, required flow, discharge pressure and temperature with Kevin.

Contact Kevin

Let’s talk about your application.

Send your fluid, operating conditions or existing pump model to Kevin.

Contact our team